Template application "Optika FilePower"

=======================================


The template application "Optika FilePower" produces single-page TIFF i-
mages, a data file and an action file with the command "Import" in its
command field.

This allows batches processed by the FilePower batch output format to be
imported into FilePower, using FPtransact for Fpmulti.

The following describes the output produced by Capture Software when u-
sing the FilePower batch output format.


Folder structure
----------------

* The FilePower batch output format will create a subfolder in the root
  export folder - check the "Path" field in the "Output" tab of the com-
  mand "Application Setup" under the "File" menu of Capture Software.

* This folder will have the same name as the current Capture Software
  batch name.

* The TIFF images will be placed in this folder, and will be named star-
  ting with "00000000.TIF" and progressing up to "99999999.TIF".

* The data file will be placed in the batch subfolder as well. The name
  of the Data file is user-definable, but it will always have the file
  extension *.LST. The default name is "DATAFILE".

* The action file can either be placed in the batch subfolder folder or
  the root export folder. The action file will always have the file ex-
  tension *.TRA. If placed in the batch subfolder, the name of the ac-
  tion file user-definable with a default name "ACTFILE". If placed in
  the root export folder, the action file will have the same name as the
  Capture Software batch name.

* For example, if a FilePower application's action file is created in
  the root export folder, and a batch named "BATCH029" is processed, the
  action file will be named "BATCH029.TRA".

* In the "Output" tab of the application setup, click on "Setup" to de-
  fine the name of the data and action files, the FilePower application
  name and subfolder name, the delete object, full text object and full
  text verify object options, and the data file field delimiter.

* The data and action file names, application name and subfolder name
  must all be defined before a batch can be processed. When changing
  their names, it is not necessary to enter the file name extensions
  and doing so will cause the extension to appear twice at the end of
  the name.

* The application name and subfolder name have no default values there-
  fore they must be given values prior to processing a batch. The maxi-
  mum length of the data file name is 255 characters. (This includes not
  only the name of the data file as it is entered in the setup, but also
  the full path to the batch output folder). The maximum length of the
  application name is 15 characters and the maximum length of the sub-
  folder name is 30.

* The option "Delete Object" has a default value of 1 (check box in set-
  up checked), the option "Full Text Object" a default value of 0 (check
  box unchecked), and the "Full Text Verify Object" a default value of 0
  (check box unchecked).

* Note that neither of the two action file fields "Command" and "Object
  Type" are user-definable; the "Command" field is always "Import" and
  the "Object Type" field is always TIFF.

* The data file field delimiter has a default value of "~" (tilde). Note
  that selecting the symbol ' or  " as a delimiter causes two delimiters
  to be written between each data file field: a single quote field deli-
  miter will always be written as '', a double quote field delimiter
  will always be written as "".

* FilePower has two types of index fields, "Folder" and "Document". All
  declared Capture Software batch index fields will be written to the
  data file as folder index fields in the order that they are declared
  in Capture Software (the first batch index field in Capture Software
  is written as the first folder index field to the data file). A maxi-
  mum of four folder index fields can be defined. As a result, declaring
  more than four Capture Software batch index fields will result in an
  error when processing the batch.

* All declared Capture Software document index fields are written, by
  default, to the data file as document index fields in the order that
  they are declared in Capture Sofware. It is possible, however, to have
  the Capture Software Document index fields written to the data file as
  folder index fields. This can be done by clicking the button "Fol-
  der/Document Index Field Assignment" in the Optika FilePower batch
  output setup.

* In the "Folder/Document Index Field Assignment" dialog, all Capture
  Software document index fields will be listed. Next to each field name
  are two radio buttons, labeled Folder and Document. Whichever button
  is selected will result in that field being written to the appropriate
  section of the Data file. If document index fields will be written to
  folder index fields in the Data file, they will be written in the or-
  der that they are declared in the "Index" tab of the application setup
  and will come after any batch index fields. The total number of Cap-
  ture Software index fields (batch or document) that can be written to
  data file Folder index fields must not exceed four. Likewise, the to-
  tal number of Capture Software document index fields that can be writ-
  ten to data file document index field must also not exceed four. If
  more than four are assigned, an error will occur either at batch pro-
  cess time or when attempting to exit the FilePower (Optika) batch out-
  put Setup dialog.